﻿<!DOCTYPE html>
<html>
<head>
<meta http-equiv="Content-Language" content="zh-CN">
<meta charset="UTF-8">
<meta name="viewport" content="width=device-width,minimum-scale=1.0,maximum-scale=1.0,user-scalable=no">
<meta content="yes" name="apple-mobile-web-app-capable" />
<meta content="black" name="apple-mobile-web-app-status-bar-style" />
<meta content="telephone=no" name="format-detection" />
<meta content="email=no" name="format-detection" />
<title>BTL检测集团</title>
<meta name="keywords" content="Inspection、certification" />
<meta name="description" content="BTL electronic product testing and certification, providing electronic product certification services in many regions at home and abroad.  " />
<link rel="stylesheet" type="text/css" href="../css/enm.css">
<script type="text/javascript" src="js/jquery-1.9.1.min.js"></script>
<script>
$(document).ready(function(){
  $(".menu h1").click(function(){
  	$(this).next("ul").slideToggle("slow");
  });
  $(".menujia").click(function(){
	$(".menu ul li div").not($(this).nextAll("div")).hide();
  	$(this).nextAll("div").slideToggle("slow");
  });
});
</script>
</head>
<body>
<div class="toper">
    <form name="topform" method="post" action="serach.php">
    	<input type="text" name="topword" value="" class="topinp" />
        <input type="submit" name="topsub" value="" class="topsub" />
    </form>
	<span class="language"><a href="user_login.php">login</a> | <a href="../m/index.php">简</a> | <a href="../fm/index.php">繁</a> | <a href="index.php" >EN</a></span>
	<div class="fl logoer"><a href="index.php" ><img src="../images/logo.jpg"></a></div>
</div>
<div class="bom">
	<span><a href="index.php">Home</a></span>
	<div class="menu">
    <h1>BTL</h1>
    <ul>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="product.php" class="m">Service Center</a>
    	<div>
        	<a href=product.php?cid=477>NCC RCB</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="industry.php" class="m">Technical platform</a>
    	<div>
        	<a href=industry.php?cid=473>Mobile Communication</a><a href=industry.php?cid=479>BQB</a><a href=industry.php?cid=472>SAR / OTA</a><a href=industry.php?cid=480>IoT</a><a href=industry.php?cid=413>EMC</a><a href=industry.php?cid=424>RF</a><a href=industry.php?cid=474>Telecom</a><a href=industry.php?cid=425>Safety</a><a href=industry.php?cid=485>New Energy</a><a href=industry.php?cid=481>Other</a><a href=industry.php?cid=486>Information security</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="zhengshu.php" class="m">Certificate</a>
    	<div>
        	<a href=zhengshu.php?cid=444>Certificate</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="about.php" class="m">About BTL</a>
    	<div>
        	<a href=about.php?id=487>Group Profile</a><a href=about.php?id=73>Complaints process</a><a href=about.php?id=237>Declaration of impartiality</a><a href=zhengshu.php>Certificate</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="join.php" class="m">Join us</a>
    	<div>
        	<a href=join.php?cid=428>Talent recruitment</a><a href=join.php?cid=429>Employees demeanor</a><a href=join.php?cid=449>The enterprise information</a>        </div>
    </li>
        
    </ul>
    </div>
    <div class="menu">
    	<h1>Global</h1>
    	<ul>
		        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=416" class="m">East Asia & South Asia</a>
        	<div>
            	<a href=news.php?cid=440>China</a><a href=news.php?cid=456>Japan</a><a href=news.php?cid=458>Indian</a><a href=news.php?cid=459>Korea</a><a href=news.php?cid=460>Taiwan</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=417" class="m">Southeast Asia</a>
        	<div>
            	<a href=news.php?cid=433>Indonesia</a><a href=news.php?cid=434>Malaysia</a><a href=news.php?cid=435>Thailand</a><a href=news.php?cid=436>Vietnam</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=418" class="m">Middle East</a>
        	<div>
            	<a href=news.php?cid=461>Saudi Arabia</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=419" class="m">Africa</a>
        	<div>
            	<a href=news.php?cid=463>South Africa</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=420" class="m">Europe</a>
        	<div>
            	<a href=news.php?cid=465>European Union</a><a href=news.php?cid=484>United Kingdom</a><a href=news.php?cid=464>Russia</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=421" class="m">South America</a>
        	<div>
            	<a href=news.php?cid=469>Argentina</a><a href=news.php?cid=470>Brazil</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=422" class="m">North America</a>
        	<div>
            	<a href=news.php?cid=466>USA</a><a href=news.php?cid=467>Canada</a><a href=news.php?cid=468>Mexico</a>            </div>
        </li>
                </ul>
    </div>
    <div class="menu">
    	<h1><a href="contact.php">Contact</a></h1>
    </div>
</div><div class="main"><img src="../upload_files/2018-12/201812110947015422.jpg" width="100%" /></div>
<ul class="lysublist">
		<li><a href=news.php?cid=465 class=cur>European Union</a></li><li><a href=news.php?cid=484 class=>United Kingdom</a></li><li><a href=news.php?cid=464 class=>Russia</a></li></ul>
<div class="main"><span class="m2posNm">Location:<a href='index.php'>Home</a> -  &gt; Europe &gt; European Union</span></div>
<div class="lyleft0000">
    	<p><img src="../upload_files/2018-12/201812110947051370.jpg" style="float:left;" />European Union<br />Voltage: 230V<br />
Frequency: 50Hz<br />
Official Language: English<br />
<br />
1.Close cooperation and connection with the certification body <br />
2.Thoughtful aftersales assistance<br />
3.Rich practical experience guidance for kinds of product<br />
</p>
    	<p>
		<a href=news.php?cid=465&leftcid=432 class=>Singapore</a><a href=news.php?cid=465&leftcid=437 class=>Questions & Answers</a><a href=news.php?cid=465&leftcid=438 class=>Certification Program</a><a href=news.php?cid=465&leftcid=439 class=cur>News</a><a href=news.php?cid=465&leftcid=471 class=>Chile</a>        </p>
</div>
<div class="main clear">
    <div class="tt">EN / IEC 62311:2020  Updated</div>
    <div class="txt2 txtimg"><p><img src="/upload_files/2020-03/1584614063510270.png" title="1584614063510270.png" alt="1584614063510270.png" width="800" height="435"/></p><p><strong>The European standard EN 62311 has been approved by CENELEC (European Committee for Electronic Technical Standards), and the official version of EN / IEC 62311: 2020 was officially released in January 2020. This standard requires mandatory requirements after 2020/7/24. For the current implementation If the products under certification are not affected, they can directly apply for the latest version.</strong></p><p>&nbsp;</p><p><span style="background-color: rgb(255, 255, 0);">Changes are shown below:</span></p><p><strong>1. A clear distinction between intentional and unintentional radiators has been introduced.</strong></p><p>&nbsp;</p><p>For unintentionally radiating equipment, the compliance assessment to emissions of E or H field shall be made according to the highest internal frequency used within the equipment under assessment or at which the equipment operates with the following criteria:</p><p>&nbsp;</p><p>– if the highest internal frequency of the equipment is less than 10 kHz, the assessments should be made up to 400 kHz;</p><p>– if the highest internal frequency of the equipment is less than 108 MHz, the assessments should be made up to 1 GHz;</p><p>– if the highest internal frequency of the equipment is between 108 MHz and 500 MHz, the assessment should be made up to 2 GHz;</p><p>– if the highest internal frequency of the equipment is between 500 MHz and 1 GHz, the assessment should be made up to 5 GHz.</p><p>If the highest internal frequency of the equipment is above 1 GHz, the assessment should be made up to 5 times the internal frequency or 6 GHz, whichever is greater.</p><p>&nbsp;</p><p><strong>2. The exposure to non-uniform fields is considered.</strong></p><p>The reference level or the maximum permissible exposure level are calculated under the assumption that a human is exposed to uniform fields.</p><p>&nbsp;</p><p>Under the situation that wavelength is longer than the distance between a human and an EM field source, for example a human is standing immediately adjacent to a high voltage transformer, the field is not uniform. If exposure is evaluated by the maximum value of field strength data at one hot spot, evaluation will be more excessive.</p><p>&nbsp;</p><p><strong>To consider non-uniformity of the fields, there are two methods:</strong></p><p>&nbsp;</p><p>1) Spatial averaging of field strength or power density (depending on the frequency and applicable exposure limit) data measured at several points assumed to be occupied by a human body. Examples of spatial averaging methods can be found in IEC 62110 for exposure around a power facility, such as a transformer, which is based on 3 to 5 measurement points, or in IEC 62232 for exposure from radiocommunication base stations.</p><p>&nbsp;</p><p>2) Compensation by using a coupling factor. This method is used for local exposure, &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;such as exposure to the fields from a domestic appliance or a small magnetic field &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;source. Examples of coupling factors for local exposure to magnetic fields are given in &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;IEC 622262- 1, or for the evaluation of a magnetic flux density in IEC 62233.</p><p>&nbsp;</p><p><strong>3. The treatment of uncertainty for the assessment procedures has been improved.</strong></p><p>&nbsp;</p><p>If the assessment uncertainty is less than or equal to a permissible maximum uncertainty Umax(Lm)/ Lm, then the measured value Lm shall be compared directly with the applicable limit Llim for the evaluation of compliance.</p><p>&nbsp;</p><p>Formula (1) shall be used to determine whether the measured value Lm complies with the reduced limit if the actual assessment uncertainty of the applicable assessment method is a permissible maximum uncertainty or more.</p><p>&nbsp;</p><p>For EMF evaluation, 30 % is often used for a permissible maximum uncertainty.</p><p><img src="/upload_files/2020-03/1584614053250100.png" title="1584614053250100.png" alt="图一.png"/></p><p><br/></p><p><strong>4. Various summation regimes are described in Annex A.</strong></p><p>&nbsp;</p><p><strong>5.Add refrance standard EN 62232: 2017</strong></p><p>&nbsp;</p><p>IEC 62232:2017, Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure.</p><p>&nbsp;</p><p><strong>6. Defined and explained for Assessment methods list on added to applicable standard list.</strong></p><p><img src="/upload_files/2020-03/1584614106116908.png" title="1584614106116908.png"/></p><p><img src="/upload_files/2020-03/1584614106491164.png" title="1584614106491164.png"/></p><p><br/></p></div>
<div><a href="news.php?cid=465"><img src=../images/back.gif border=0></a><a href=#><img src=../images/top_x.gif border=0></a></div>
</div>
<div class="end">
	<p><strong>LINK：</strong>
	<a href=https://www.globalcertificationforum.org/ target=_blank>GCF</a><a href=https://www.ptcrb.com/ target=_blank>PTCRB</a></p>
Copyright © 2008-2019 BTL Inc.  All Rights Reserved  ICP NO.18145055</div>
</body>
</html>