﻿<!DOCTYPE html>
<html>
<head>
<meta http-equiv="Content-Language" content="zh-CN">
<meta charset="UTF-8">
<meta name="viewport" content="width=device-width,minimum-scale=1.0,maximum-scale=1.0,user-scalable=no">
<meta content="yes" name="apple-mobile-web-app-capable" />
<meta content="black" name="apple-mobile-web-app-status-bar-style" />
<meta content="telephone=no" name="format-detection" />
<meta content="email=no" name="format-detection" />
<title>BTL检测集团</title>
<meta name="keywords" content="Inspection、certification" />
<meta name="description" content="BTL electronic product testing and certification, providing electronic product certification services in many regions at home and abroad.  " />
<link rel="stylesheet" type="text/css" href="../css/enm.css">
<script type="text/javascript" src="js/jquery-1.9.1.min.js"></script>
<script>
$(document).ready(function(){
  $(".menu h1").click(function(){
  	$(this).next("ul").slideToggle("slow");
  });
  $(".menujia").click(function(){
	$(".menu ul li div").not($(this).nextAll("div")).hide();
  	$(this).nextAll("div").slideToggle("slow");
  });
});
</script>
</head>
<body>
<div class="toper">
    <form name="topform" method="post" action="serach.php">
    	<input type="text" name="topword" value="" class="topinp" />
        <input type="submit" name="topsub" value="" class="topsub" />
    </form>
	<span class="language"><a href="user_login.php">login</a> | <a href="../m/index.php">简</a> | <a href="../fm/index.php">繁</a> | <a href="index.php" >EN</a></span>
	<div class="fl logoer"><a href="index.php" ><img src="../images/logo.jpg"></a></div>
</div>
<div class="bom">
	<span><a href="index.php">Home</a></span>
	<div class="menu">
    <h1>BTL</h1>
    <ul>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="product.php" class="m">Service Center</a>
    	<div>
        	<a href=product.php?cid=477>NCC RCB</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="industry.php" class="m">Technical platform</a>
    	<div>
        	<a href=industry.php?cid=473>Mobile Communication</a><a href=industry.php?cid=479>BQB</a><a href=industry.php?cid=472>SAR / OTA</a><a href=industry.php?cid=480>IoT</a><a href=industry.php?cid=413>EMC</a><a href=industry.php?cid=424>RF</a><a href=industry.php?cid=474>Telecom</a><a href=industry.php?cid=425>Safety</a><a href=industry.php?cid=485>New Energy</a><a href=industry.php?cid=481>Other</a><a href=industry.php?cid=486>Information security</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="zhengshu.php" class="m">Certificate</a>
    	<div>
        	<a href=zhengshu.php?cid=444>Certificate</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="about.php" class="m">About BTL</a>
    	<div>
        	<a href=about.php?id=487>Group Profile</a><a href=about.php?id=73>Complaints process</a><a href=about.php?id=237>Declaration of impartiality</a><a href=zhengshu.php>Certificate</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="join.php" class="m">Join us</a>
    	<div>
        	<a href=join.php?cid=428>Talent recruitment</a><a href=join.php?cid=429>Employees demeanor</a><a href=join.php?cid=449>The enterprise information</a>        </div>
    </li>
        
    </ul>
    </div>
    <div class="menu">
    	<h1>Global</h1>
    	<ul>
		        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=416" class="m">East Asia & South Asia</a>
        	<div>
            	<a href=news.php?cid=440>China</a><a href=news.php?cid=456>Japan</a><a href=news.php?cid=458>Indian</a><a href=news.php?cid=459>Korea</a><a href=news.php?cid=460>Taiwan</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=417" class="m">Southeast Asia</a>
        	<div>
            	<a href=news.php?cid=433>Indonesia</a><a href=news.php?cid=434>Malaysia</a><a href=news.php?cid=435>Thailand</a><a href=news.php?cid=436>Vietnam</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=418" class="m">Middle East</a>
        	<div>
            	<a href=news.php?cid=461>Saudi Arabia</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=419" class="m">Africa</a>
        	<div>
            	<a href=news.php?cid=463>South Africa</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=420" class="m">Europe</a>
        	<div>
            	<a href=news.php?cid=465>European Union</a><a href=news.php?cid=484>United Kingdom</a><a href=news.php?cid=464>Russia</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=421" class="m">South America</a>
        	<div>
            	<a href=news.php?cid=469>Argentina</a><a href=news.php?cid=470>Brazil</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=422" class="m">North America</a>
        	<div>
            	<a href=news.php?cid=466>USA</a><a href=news.php?cid=467>Canada</a><a href=news.php?cid=468>Mexico</a>            </div>
        </li>
                </ul>
    </div>
    <div class="menu">
    	<h1><a href="contact.php">Contact</a></h1>
    </div>
</div><div class="lyleft">
    	<ul>
		<li><a href=industry.php?cid=473 class=>Mobile Communication</a></li><li><a href=industry.php?cid=479 class=>BQB</a></li><li><a href=industry.php?cid=472 class=>SAR / OTA</a></li><li><a href=industry.php?cid=480 class=>IoT</a></li><li><a href=industry.php?cid=413 class=cur>EMC</a></li><li><a href=industry.php?cid=424 class=>RF</a></li><li><a href=industry.php?cid=474 class=>Telecom</a></li><li><a href=industry.php?cid=425 class=>Safety</a></li><li><a href=industry.php?cid=485 class=>New Energy</a></li><li><a href=industry.php?cid=481 class=>Other</a></li><li><a href=industry.php?cid=486 class=>Information security</a></li>        </ul>
</div>
<div class="main"><span class="m2posNm">Location:<a href='index.php'>Home</a> - Technical platform - EMC</span></div>
<div class="main clear">
	<div class="tt">Interpretation|The new version of the IEC standard for electrostatic testing has stricter requirements for electrostatic gun calibration</div>
	<div class="txt2 txtimg"><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">The IEC electrostatic standard has not been updated for more than ten years, and there are still some changes in the overall layout compared to the previous version. Follow me to learn about the changes that need to be focused on:</span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><br/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><strong><span style="font-size: 18px;">Table 2 - General ESD generator parameters</span></strong></p><p><img src="/upload_files/2025-07/1752040775857494.jpg" title="1752040775857494.jpg" alt="1752040775857494.jpg" width="500" height="356"/></p><p><strong><span style="font-family: 宋体; text-wrap-mode: wrap; font-size: 18px;"><br/></span></strong></p><p><strong><span style="font-family: 宋体; text-wrap-mode: wrap; font-size: 18px;">Table 3 Discharge current waveform parameters</span></strong></p><p><img src="/upload_files/2025-07/1752040855117683.jpg" title="1752040855117683.jpg" alt="1752040855117683.jpg" width="800" height="408"/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;"><strong>Observant you should have already noticed:</strong></span></p><ul class=" list-paddingleft-2" style="font-family: Verdana; font-size: 12px; text-wrap-mode: wrap;"><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;"><strong>The contact discharge in Table 2 has been updated from 1 kV to 2 KV at least initially;</strong></span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;"><strong>The yellow section in Table 3 has added calibration requirements for ESD generators with air discharge tips;</strong></span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;"><strong>It can also be seen from Table 3 that for electrostatic guns supporting up to 15 kV, 15 kV waveform calibration is required.</strong></span></p></li></ul><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><br/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">Take a look at the waveform diagram of the 4 kV calibration current for electrostatic contact discharge in the new standard:</span></p><p><img src="/upload_files/2025-07/1752040913566470.png" title="1752040913566470.png" alt="3.png"/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;"><strong>At the same time, some updates have been made to the current calibration program;</strong></span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;"><strong>Of course, for the open circuit output voltage, it is necessary to measure the open circuit output voltage of the ESD generator when the discharge switch is closed and meet the requirements of Table 2.</strong></span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><br/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">Measurement steps for current waveform parameters of ESD generator:</span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">1. Record the waveform of five discharges (five positive and five negative polarity).</span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">2. Measure the following parameters (see Figure 2 and Table 3) and ensure that each value is within the allowable range:</span></p><ul class=" list-paddingleft-2" style="font-family: Verdana; font-size: 12px; text-wrap-mode: wrap;"><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;"><span class="s12" style="font-size: 16px; font-style: italic;">I</span><span class="s13" style="vertical-align: sub; font-size: smaller;">p1</span>: First peak current (A)</span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="background-color: rgb(255, 255, 0); font-size: 18px;">Ip2: Second peak current (A)</span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;"><span class="s12" style="font-size: 16px; font-style: italic;">I</span><span class="s13" style="vertical-align: sub; font-size: smaller;">30</span>: Current at 30 ns after discharge (A)</span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;"><span class="s12" style="font-size: 16px; font-style: italic;">I</span><span class="s13" style="vertical-align: sub; font-size: smaller;">60</span>: Current at 60 ns after discharge (A)</span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;">TR: Current rise time (ns)</span></p></li></ul><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">3. At least one waveform of 8 kV positive polarity contact discharge should be included in the calibration report.</span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><br/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;"><strong>The measurement of&nbsp;<span class="s12" style="font-size: 16px; font-style: italic;">I</span><span class="s13" style="vertical-align: sub; font-size: smaller;">p2</span>&nbsp;points has been added to the calibration program, and the 2025 standard emphasizes that at least one waveform of 8 kV positive polarity contact discharge should be included in the report.</strong></span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><br/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;"><strong>Let&#39;s compare some changes in the calibration target board configuration between the 2025 and 2008 versions:</strong></span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><br/></p><p class="p11" style="margin-bottom: 0.111111in; font-family: 宋体; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-weight: bold; background-color: yellow; font-size: 18px;">IEC 61000-4-2:2025</span></p><p class="p11" style="margin-bottom: 0.111111in; font-family: 宋体; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-weight: bold; background-color: rgb(255, 255, 255); font-size: 18px;"><img src="/upload_files/2025-07/1752040988134706.png" title="1752040988134706.png" alt="1752040988134706.png" width="436" height="400"/></span></p><p class="p11" style="margin-bottom: 0.111111in; font-family: 宋体; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-weight: bold; background-color: yellow; font-size: 18px;"><br/></span></p><p class="p11" style="margin-bottom: 0.111111in; font-family: 宋体; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-weight: bold; background-color: yellow; font-size: 18px;">IEC 61000-4-2:2008</span></p><p><img src="/upload_files/2025-07/1752041017288657.png" title="1752041017288657.png" alt="1752041017288657.png" width="446" height="400"/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;"><strong>The new version has added normative attachments for specific equipment testing devices</strong></span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">Small wall mounted EUTs; When EUT&lt;(0.5*0.5) m, the center of VCP should be located at the center of both sides of EUT.</span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">Wall mounted equipment should be installed on walls without conductive structures or embedded in walls, and should be set up according to the example shown in Figure I.1;</span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">NOTE A&nbsp; Similar insulation brackets can be used, but without metal plates, as shown in Figure I.2.</span></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;">If the EUT is intended to be installed on a conductive surface, the test setup is shown in Figure I.2,t<span style="font-size: 11pt;">he size of the metal in Figure I.2 should exceed the EUT by at least 0.5 m in all directions.</span></span></p><p><span style="font-size: 18px;"><img src="/upload_files/2025-07/1752041045121018.png" title="1752041045121018.png" alt="1752041045121018.png" width="422" height="400"/>&nbsp; <img src="/upload_files/2025-07/1752041070641819.png" title="1752041070641819.png" alt="1752041070641819.png" width="519" height="400"/></span></p><p><span style="font-size: 18px;"></span></p><p><br/></p><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-size: 18px;"><strong>Other differences between IEC 61000-4-2 2025 and the previous version:</strong></span></p><ul class=" list-paddingleft-2" style="font-family: Verdana; font-size: 12px; text-wrap-mode: wrap;"><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;">Added an informative annex on how to select test points and give guidance on how to specify the number of pulses for direct contact discharges (see Annex E);</span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;">Moved Clause 9 into a new informative annex (see Annex K);</span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;">Improved measurement uncertainty considerations with examples of uncertainty budgets;</span></p></li><li><p class="p10" style="text-indent: -0.305556in; margin-left: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt;"><span style="font-size: 18px;">Moved post-installation tests into a new informative Annex G since they cannot be performed in a controlled environment.</span></p></li></ul><p class="p1" style="margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><br/></p><p class="p12" style="text-indent: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-weight: bold; font-size: 18px;">The editor will tell you a secret:</span></p><p class="p12" style="text-indent: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-weight: bold; font-size: 18px;">The electrostatic guns at the two BTL static testing sites in southern China can support a testing strength of 30kV, which is sufficient to meet most standard testing requirements; BTL has been deeply involved in the testing industry for many years and has rich experience. In the South China region, it has a well-defined EMC engineering team with dedicated installation personnel, project evaluation management personnel, and on-site testing personnel, achieving greater professionalism, meticulousness, and efficiency; And the venue resources are abundant, with multiple complete sets of EMC equipment.</span></p><p class="p12" style="text-indent: 0.305556in; margin-bottom: 0.111111in; font-family: &quot;Times New Roman&quot;; font-size: 11pt; text-wrap-mode: wrap;"><span style="font-weight: bold; font-size: 18px;">If you want to learn more about EMC related issues, you can call us for consultation. We are enthusiastic to answer your questions and welcome your call</span></p><p></p></div>
	<div style="float:right"><a href="industry.php"><img src=../images/back.gif border=0></a><a href=#><img src=../images/top_x.gif border=0></a></div>
</div>
<div class="end">
	<p><strong>LINK：</strong>
	<a href=https://www.globalcertificationforum.org/ target=_blank>GCF</a><a href=https://www.ptcrb.com/ target=_blank>PTCRB</a></p>
Copyright © 2008-2019 BTL Inc.  All Rights Reserved  ICP NO.18145055</div>
</body>
</html>