﻿<!DOCTYPE html>
<html>
<head>
<meta http-equiv="Content-Language" content="zh-CN">
<meta charset="UTF-8">
<meta name="viewport" content="width=device-width,minimum-scale=1.0,maximum-scale=1.0,user-scalable=no">
<meta content="yes" name="apple-mobile-web-app-capable" />
<meta content="black" name="apple-mobile-web-app-status-bar-style" />
<meta content="telephone=no" name="format-detection" />
<meta content="email=no" name="format-detection" />
<title>BTL检测集团</title>
<meta name="keywords" content="Inspection、certification" />
<meta name="description" content="BTL electronic product testing and certification, providing electronic product certification services in many regions at home and abroad.  " />
<link rel="stylesheet" type="text/css" href="../css/enm.css">
<script type="text/javascript" src="js/jquery-1.9.1.min.js"></script>
<script>
$(document).ready(function(){
  $(".menu h1").click(function(){
  	$(this).next("ul").slideToggle("slow");
  });
  $(".menujia").click(function(){
	$(".menu ul li div").not($(this).nextAll("div")).hide();
  	$(this).nextAll("div").slideToggle("slow");
  });
});
</script>
</head>
<body>
<div class="toper">
    <form name="topform" method="post" action="serach.php">
    	<input type="text" name="topword" value="" class="topinp" />
        <input type="submit" name="topsub" value="" class="topsub" />
    </form>
	<span class="language"><a href="user_login.php">login</a> | <a href="../m/index.php">简</a> | <a href="../fm/index.php">繁</a> | <a href="index.php" >EN</a></span>
	<div class="fl logoer"><a href="index.php" ><img src="../images/logo.jpg"></a></div>
</div>
<div class="bom">
	<span><a href="index.php">Home</a></span>
	<div class="menu">
    <h1>BTL</h1>
    <ul>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="product.php" class="m">Service Center</a>
    	<div>
        	<a href=product.php?cid=477>NCC RCB</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="industry.php" class="m">Technical platform</a>
    	<div>
        	<a href=industry.php?cid=473>Mobile Communication</a><a href=industry.php?cid=479>BQB</a><a href=industry.php?cid=472>SAR / OTA</a><a href=industry.php?cid=480>IoT</a><a href=industry.php?cid=413>EMC</a><a href=industry.php?cid=424>RF</a><a href=industry.php?cid=474>Telecom</a><a href=industry.php?cid=425>Safety</a><a href=industry.php?cid=485>New Energy</a><a href=industry.php?cid=481>Other</a><a href=industry.php?cid=486>Information security</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="zhengshu.php" class="m">Certificate</a>
    	<div>
        	<a href=zhengshu.php?cid=444>Certificate</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="about.php" class="m">About BTL</a>
    	<div>
        	<a href=about.php?id=487>Group Profile</a><a href=about.php?id=73>Complaints process</a><a href=about.php?id=237>Declaration of impartiality</a><a href=zhengshu.php>Certificate</a>        </div>
    </li>
        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="join.php" class="m">Join us</a>
    	<div>
        	<a href=join.php?cid=428>Talent recruitment</a><a href=join.php?cid=429>Employees demeanor</a><a href=join.php?cid=449>The enterprise information</a>        </div>
    </li>
        
    </ul>
    </div>
    <div class="menu">
    	<h1>Global</h1>
    	<ul>
		        <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=416" class="m">East Asia & South Asia</a>
        	<div>
            	<a href=news.php?cid=440>China</a><a href=news.php?cid=456>Japan</a><a href=news.php?cid=458>Indian</a><a href=news.php?cid=459>Korea</a><a href=news.php?cid=460>Taiwan</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=417" class="m">Southeast Asia</a>
        	<div>
            	<a href=news.php?cid=433>Indonesia</a><a href=news.php?cid=434>Malaysia</a><a href=news.php?cid=435>Thailand</a><a href=news.php?cid=436>Vietnam</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=418" class="m">Middle East</a>
        	<div>
            	<a href=news.php?cid=461>Saudi Arabia</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=419" class="m">Africa</a>
        	<div>
            	<a href=news.php?cid=463>South Africa</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=420" class="m">Europe</a>
        	<div>
            	<a href=news.php?cid=465>European Union</a><a href=news.php?cid=484>United Kingdom</a><a href=news.php?cid=464>Russia</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=421" class="m">South America</a>
        	<div>
            	<a href=news.php?cid=469>Argentina</a><a href=news.php?cid=470>Brazil</a>            </div>
        </li>
                <li><img src="../images/pro_c_jia.gif" class="menujia" /><a href="global.php?cid=422" class="m">North America</a>
        	<div>
            	<a href=news.php?cid=466>USA</a><a href=news.php?cid=467>Canada</a><a href=news.php?cid=468>Mexico</a>            </div>
        </li>
                </ul>
    </div>
    <div class="menu">
    	<h1><a href="contact.php">Contact</a></h1>
    </div>
</div><div class="lyleft">
    	<ul>
		<li><a href=industry.php?cid=473 class=>Mobile Communication</a></li><li><a href=industry.php?cid=479 class=>BQB</a></li><li><a href=industry.php?cid=472 class=>SAR / OTA</a></li><li><a href=industry.php?cid=480 class=>IoT</a></li><li><a href=industry.php?cid=413 class=cur>EMC</a></li><li><a href=industry.php?cid=424 class=>RF</a></li><li><a href=industry.php?cid=474 class=>Telecom</a></li><li><a href=industry.php?cid=425 class=>Safety</a></li><li><a href=industry.php?cid=485 class=>New Energy</a></li><li><a href=industry.php?cid=481 class=>Other</a></li><li><a href=industry.php?cid=486 class=>Information security</a></li>        </ul>
</div>
<div class="main"><span class="m2posNm">Location:<a href='index.php'>Home</a> - Technical platform - EMC</span></div>
<div class="main clear">
	<div class="tt">Do I need to test DIP for DC input devices?</div>
	<div class="txt2 txtimg"><p><span style="color: rgb(255, 0, 0);"><strong><span style="text-wrap: nowrap;">What is DC DIP?</span></strong></span></p><p><span style="text-wrap: nowrap;">Simulating transient voltage drops and interruptions caused by faults (short circuit or ground fault) in the DC power supply network; And voltage changes caused by continuous changes in loads connected to the grid.</span></p><p><span style="text-wrap: nowrap;"><br/></span></p><hr/><p><strong><span style="text-wrap: nowrap; color: rgb(255, 0, 0);">Why test DIPs?</span></strong></p><p><span style="text-wrap: nowrap;">Dips often occurs in our daily life. When the power supply system is unstable or overloaded, the voltage may suddenly drop or interrupt, which may make the electronic products working in the same power grid malfunction or even explode and damage.</span></p><p><span style="text-wrap: nowrap;"><br/></span></p><hr/><p><span style="color: rgb(255, 0, 0);"><strong><span style="text-wrap: nowrap;">So what items does DC DIP need to test?</span></strong></span></p><p><span style="text-wrap: nowrap;">DC DIP test requirements are performed according to EN IEC 61000-4-29; The requirements are as follows:</span></p><p><br/></p><p><strong><span style="text-wrap: nowrap;">1. Test voltage selection</span></strong></p><p><span style="text-wrap: nowrap;"><br/></span></p><p><span style="text-wrap: nowrap;">When the equipment has a rated voltage range, the following provisions should be adopted:</span></p><p><span style="text-wrap: nowrap;"><br/></span></p><p><span style="text-wrap: nowrap;">&gt; If the voltage range does not exceed 20% of the lower voltage specified for the rated voltage range, a voltage test may be specified within that range.</span></p><p><span style="text-wrap: nowrap;">&gt; In other cases, the test procedure shall be applied to the minimum and maximum voltages declared within the voltage range.</span></p><p><span style="text-wrap: nowrap; color: rgb(84, 141, 212);">Ps: BTL uses 3ctest test equipment to support product testing in the range of voltage DC 0-450V and current 0-50A.</span></p><p><br/></p><p><span style="text-wrap: nowrap;">&nbsp;<strong>2. Test project</strong></span></p><p><span style="text-wrap: nowrap;"><br/></span></p><p><span style="text-wrap: nowrap;">When the EUT (sample under test) is in a typical operating state, we need to test for the following items:</span></p><p><span style="text-wrap: nowrap;">2.1 Voltage dip</span></p><p><img src="/upload_files/2023-11/1698982538395634.png" title="1698982538395634.png" alt="2.png"/></p><p><span style="text-wrap: nowrap;">&nbsp;Test Level 40% and 70% (%UT) voltage dips, that is, when the current voltage of the EUT is reduced by 60% and 30%, check whether the EUT can operate in typical mode.</span></p><p><br/></p><p><span style="text-wrap: nowrap;">2.2 Voltage Interruption</span></p><p><span style="text-wrap: nowrap;"><img src="/upload_files/2023-11/1698982550118703.png" title="1698982550118703.png" alt="3.png"/></span></p><p><span style="text-wrap: nowrap;">Voltage interruption means that the current EUT voltage drops by 100%, which is equivalent to the state of power failure; At this time, the test generator should be set in the following two states:</span></p><p><span style="text-wrap: nowrap;">&gt; Block the reverse current from the load (high impedance)</span></p><p><span style="text-wrap: nowrap;">&gt; Absorbed load reverse current (low impedance)</span></p><p><br/></p><p><span style="text-wrap: nowrap;">2.3 Voltage Variation</span></p><p><span style="text-wrap: nowrap;"><img src="/upload_files/2023-11/1698982571781715.png" title="1698982571781715.png" alt="4.png"/></span></p><p><span style="text-wrap: nowrap;">Test levels are divided into 85% and 120%, or 80% and 120%, or other grades, and the test level is selected by the manufacturer.</span></p><p><span style="text-wrap: nowrap;"><br/></span></p><p><span style="text-wrap: nowrap;">2.1 &amp; 2.2 &amp; 2.3 The number of trials was 3 times, and the minimum interval between the two trials was 10 s.</span></p><p><span style="text-wrap: nowrap;"><br/></span></p><hr/><p><span style="color: rgb(255, 0, 0);"><strong><span style="text-wrap: nowrap;">How are DC DIP test results determined?</span></strong></span></p><p><br/></p><p><span style="text-wrap: nowrap;">The EN IEC 61000-4-29 standard specifies that test results should be classified according to loss of function or degradation of performance of the EUT.</span></p><p><span style="text-wrap: nowrap;">These classifications relate to the performance registration specified by the manufacturer, the applicant for the test, or agreed between the manufacturer and the user; The recommended categories are as follows:</span></p><p><span style="text-wrap: nowrap;"><br/></span></p><p><span style="text-wrap: nowrap;">A) Normal performance within the limit values specified by the manufacturer, applicant or user;</span></p><p><span style="text-wrap: nowrap;">B) the function or performance is temporarily reduced or lost, but after the interference stops, the device under test can automatically resume its normal performance without operator intervention;</span></p><p><span style="text-wrap: nowrap;">C) temporary loss of function or degradation of performance requiring operator intervention to correct;</span></p><p><span style="text-wrap: nowrap;">D) Loss of functionality or degradation of performance that cannot be recovered due to hardware or software damage or data loss.</span></p><p><br/></p><p><span style="text-wrap: nowrap;">The manufacturer&#39;s instructions can define which effects on the EUT are negligible or acceptable. In the absence of a suitable generic, product or product class standard, the classification can serve as a guide for the development of performance standards by the General, Product and Product Family Standards Committee, or as a framework for a performance standard agreement between manufacturers and buyers, for example in the absence of a suitable generic, product or product family standard.</span></p><p><span style="text-wrap: nowrap;"><br/></span></p><p><span style="text-wrap: nowrap;"><br/></span></p><p><img src="/upload_files/2023-11/1698982047117433.jpg" title="1698982047117433.jpg" width="205" height="300" alt="1698982047117433.jpg"/>&nbsp;&nbsp;<img src="/upload_files/2023-11/1698982047611567.jpg" title="1698982047611567.jpg" width="234" height="300" alt="1698982047611567.jpg"/></p><p><span style="text-wrap: nowrap;">BTL has completed the environment construction of DC DIP in September and has been verified by CEPREI, and can provide pre-test services for customers and friends. At the same time, we are working hard to apply for domestic and foreign qualifications, welcome to contact the BTL team, BTL will share with you the most professional and comprehensive certification information.</span></p><p><br/></p></div>
	<div style="float:right"><a href="industry.php"><img src=../images/back.gif border=0></a><a href=#><img src=../images/top_x.gif border=0></a></div>
</div>
<div class="end">
	<p><strong>LINK：</strong>
	<a href=https://www.globalcertificationforum.org/ target=_blank>GCF</a><a href=https://www.ptcrb.com/ target=_blank>PTCRB</a></p>
Copyright © 2008-2019 BTL Inc.  All Rights Reserved  ICP NO.18145055</div>
</body>
</html>